Deep Discharge in Batteries: Causes, Detection and Management

21/03/2025
  • Definition and Causes of Deep Discharge

    • Deep discharge of a battery occurs when the cell voltage drops below its normal operating range, typically between 2.5 and 3.0 volts. Under normal conditions, the integrated Battery Management System (BMS) protects the battery against this phenomenon. However, there are situations in which this protection may fail.
    • The main causes of deep discharge include:
      • BMS failure: A defect in the BMS electronics can prevent it from properly protecting the battery.
      • Prolonged storage without charge: Prolonged storage of the battery without periodic charging allows the cell voltage to gradually decrease, which can result in deep discharge.
  • Detection of Deep Discharge

    • Detecting deep discharge can be complex, especially for non-specialized users. Common symptoms include:
      • Inability to charge the battery: The battery does not accept charge or exhibits unusually long charging times.
      • Failure in voltage supply: The battery does not provide voltage or does so insufficiently.
      • Abnormal device operation: In the case of electric bicycles, the device may not start even though the battery indicates a full charge.
    • If deep discharge is suspected, it is recommended to suspend battery use.
  • Management of Deep Discharge

    • It is important to note that if the battery already had autonomy problems before the deep discharge, it may be advisable to replace the cells. In these cases, all cells can be replaced with new ones, ensuring a range equal to or greater than the original.